Immunomagnetic Separation of B Type Acute Lymphoblastic Leukemia Cells from Bone Marrow With Flow Cytometry Validation and Microfluidic Chip Measurements

relationships.isProjectOf

relationships.isJournalIssueOf

Abstract

In order to detect the blast cells from bone marrow of patients, one strategy is to first isolate the cells using immunomagnetic beads. The aim of this study was to report the experimental results of the immunomagnetic separation efficiency of the blast cells from bone marrow of pediatric leukemia patients. To test the efficiency of immunomagnetic separation, flow cytometry measurements at critical steps were performed. We here reported 94.5% capture efficiency for CD10 nano beads. Patients samples were also analyzed with a microfluidic chip to test the feasibility for further developments.

Description

Deniz, Gunnur/0000-0002-0721-6213; Murat-Cifci, Aysegul/0000-0002-6823-4175; Eken, Ahmet/0000-0002-5816-0686; Icoz, Kutay/0000-0002-0947-6166; Ozcan, Servet/0000-0002-9914-8843;

Keywords

B Type Acute Lymphoblastic Leukemia, Immunomagnetic Separation, Flow Cytometry, Bone Marrow, Hematogone, Microfluidic Chip, bone marrow, flow cytometry, B type acute lymphoblastic leukemia, hematogone, microfluidic chip, immunomagnetic separation

Fields of Science

0301 basic medicine, 0303 health sciences, 03 medical and health sciences

Citation

WoS Q

Scopus Q

OpenCitations Logo
OpenCitations Citation Count
11

Volume

56

Issue

15

Start Page

2659

End Page

2666