All-Polymer Ultrasonic Transducer Design for an Intravascular Ultrasonography Application

dc.contributor.author Hah, Dooyoung
dc.date.accessioned 2025-09-25T10:40:11Z
dc.date.available 2025-09-25T10:40:11Z
dc.date.issued 2019
dc.description Hah, Dooyoung/0000-0002-1290-0597 en_US
dc.description.abstract Intravascular ultrasonography (IVUS), a medical imaging modality, is used to obtain cross-sectional views of blood vessels from inside. In IVUS, transducers are brought to the proximity of the imaging targets so that high-resolution images can be obtained at high frequency without much concern of signal attenuation. To eliminate mechanical rotation rendered in conventional IVUS, it is proposed to manufacture a transducer array on a flexible substrate and wrap it around a cylindrical frame. The transducer of consideration is a capacitive micromachined ultrasonic transducer (CMUT). The whole device needs to be made out of polymers to be able to endure a high degree of bending (radius: 1 mm) Bending of the devices leads to considerable changes in the device characteristics, including resonant frequency and pull-in voltage due to geometrical dimension changes and stress induced. The main purpose of this work is to understand the effect of bending on the device characteristics by means of finite element analysis. Another objective of the work is to understand the relationships between such an effect and the device geometries. It is learned that the bending-induced stress depends strongly on anchor width, membrane thickness, and substrate thickness. It is also learned that resonant frequency and pull-in voltage become lower in most cases because of using a flexible substrate in comparison to those of the device on a rigid substrate. Bending-induced stress increases the spring constant and hence increases resonant frequency and pull-in voltage, although this effect is relatively weaker. For most of the device geometries, pull-in voltage is too high for the polymer material to endure. This is the main drawback of the all-polymer CMUT. In order to meet the design goal of 20 MHz resonant frequency, the membrane radius has to be smaller than 7.7 mu m for a thickness of 3 mu m. en_US
dc.description.sponsorship Research Fund of Abdullah Gul University [FOA-2016-49] en_US
dc.description.sponsorship This work was partially supported by the Research Fund of Abdullah Gul University (Project Number: FOA-2016-49). en_US
dc.identifier.doi 10.3906/elk-1901-233
dc.identifier.issn 1300-0632
dc.identifier.issn 1303-6203
dc.identifier.scopus 2-s2.0-85072619425
dc.identifier.uri https://doi.org/10.3906/elk-1901-233
dc.identifier.uri https://search.trdizin.gov.tr/en/yayin/detay/337146/all-polymer-ultrasonic-transducer-design-for-an-intravascular-ultrasonography-application
dc.identifier.uri https://hdl.handle.net/20.500.12573/3213
dc.language.iso en en_US
dc.publisher Tubitak Scientific & Technological Research Council Turkey en_US
dc.relation.ispartof Turkish Journal of Electrical Engineering and Computer Sciences en_US
dc.rights info:eu-repo/semantics/closedAccess en_US
dc.subject Polymer Microelectromechanical Systems en_US
dc.subject Ultrasonic Transducer en_US
dc.subject Flexible Substrate en_US
dc.subject Intravascular Ultrasonography en_US
dc.title All-Polymer Ultrasonic Transducer Design for an Intravascular Ultrasonography Application en_US
dc.type Article en_US
dspace.entity.type Publication
gdc.author.id Hah, Dooyoung/0000-0002-1290-0597
gdc.author.institutional Hah, Dooyoung
gdc.author.scopusid 6701711129
gdc.author.wosid Hah, Dooyoung/A-7587-2009
gdc.bip.impulseclass C5
gdc.bip.influenceclass C5
gdc.bip.popularityclass C5
gdc.coar.access metadata only access
gdc.coar.type text::journal::journal article
gdc.collaboration.industrial false
gdc.description.department Abdullah Gül University en_US
gdc.description.departmenttemp [Hah, Dooyoung] Abdullah Gul Univ, Fac Engn, Dept Elect & Elect Engn, Kayseri, Turkey en_US
gdc.description.endpage 2455 en_US
gdc.description.issue 4 en_US
gdc.description.publicationcategory Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı en_US
gdc.description.scopusquality Q2
gdc.description.startpage 2444 en_US
gdc.description.volume 27 en_US
gdc.description.woscitationindex Science Citation Index Expanded
gdc.description.wosquality Q3
gdc.identifier.openalex W2966393132
gdc.identifier.trdizinid 337146
gdc.identifier.wos WOS:000482742800005
gdc.index.type WoS
gdc.index.type Scopus
gdc.index.type TR-Dizin
gdc.oaire.accesstype GOLD
gdc.oaire.diamondjournal false
gdc.oaire.downloads 171
gdc.oaire.impulse 3.0
gdc.oaire.influence 2.6247728E-9
gdc.oaire.isgreen true
gdc.oaire.keywords Polymer microelectromechanical systems
gdc.oaire.keywords ultrasonic transducer
gdc.oaire.keywords flexible substrate
gdc.oaire.keywords intravascular ultrasonography
gdc.oaire.popularity 3.6712042E-9
gdc.oaire.publicfunded false
gdc.oaire.sciencefields 0103 physical sciences
gdc.oaire.sciencefields 01 natural sciences
gdc.oaire.views 166
gdc.openalex.fwci 0.508
gdc.openalex.normalizedpercentile 0.68
gdc.opencitations.count 4
gdc.plumx.crossrefcites 3
gdc.plumx.mendeley 11
gdc.plumx.scopuscites 4
gdc.scopus.citedcount 4
gdc.virtual.author Hah, Dooyoung
gdc.wos.citedcount 4
relation.isAuthorOfPublication 65dd5264-c1ce-4cbf-9a43-714fc00e2732
relation.isAuthorOfPublication.latestForDiscovery 65dd5264-c1ce-4cbf-9a43-714fc00e2732
relation.isOrgUnitOfPublication 665d3039-05f8-4a25-9a3c-b9550bffecef
relation.isOrgUnitOfPublication ef13a800-4c99-4124-81e0-3e25b33c0c2b
relation.isOrgUnitOfPublication f22f14aa-23ad-40e4-bc25-b9705d4051ed
relation.isOrgUnitOfPublication.latestForDiscovery 665d3039-05f8-4a25-9a3c-b9550bffecef

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
All-polymer ultrasonic transducer design for an intravascular ultrasonography application.pdf
Size:
4.14 MB
Format:
Adobe Portable Document Format
Description:
Makale

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: