Optimization of carbon dioxide absorption in a continuous bubble column reactor using response surface methodology

dc.contributor.author Gul, Ayşe
dc.contributor.author Derakhshandeh, Masoud
dc.contributor.author Un, Umran Tezcan
dc.contributor.authorID 0000-0002-2305-6408 en_US
dc.contributor.department AGÜ, Mühendislik Fakültesi, İnşaat Mühendisliği Bölümü en_US
dc.contributor.institutionauthor Gul, Ayşe
dc.date.accessioned 2024-03-29T07:41:40Z
dc.date.available 2024-03-29T07:41:40Z
dc.date.issued 2023 en_US
dc.description.abstract Carbon dioxide absorption using amine based solvents is a well-known approach for carbon dioxide removal. Especially with the increasing concerns about greenhouse gas emissions, there is a need for an optimization approach capable of multifactor calibration and prediction of interactions. Since conventional methods based on empirical relations are not efficiently applicable, this study investigates use of Response Surface Methodology as a strong optimization tool. A bubble column reactor was used and the effect of solvent concentration (10.0, 20.0 and 30.0 vol%), flow rate (4.0, 5.0 and 6.0 L min−1), diffuser pore size (0.5, 1.0 and 1.5 mm) and temperature (20.0, 25.0 and 30.0°C) on the absorption capacity and also overall mass transfer coefficient was evaluated. The optimization results for maintaining maximum capacity and overall mass transfer coefficient revealed that different optimization targets led to different tuned operational factors. Overall mass transfer coefficient decreased to 34.7 min−1 when the maximum capacity was the desired target. High reaction rate along with the highest absorption capacity was set as desirable two factor target in this application. As a result, a third scenario was designed to maximize both mass transfer coefficient and absorption capacity simultaneously. The optimized condition was achieved when a gas flow rate of 5.9 L min−1, MEA solution of 29.6 vol%, diffuser pore size of 0.5 mm and temperature of 20.6°C was adjusted. At this condition, mass transfer coefficient reached a maximum of 38.4 min−1, with a forecasted achievable absorption capacity of 120.5 g CO2 per kg MEA. en_US
dc.identifier.endpage 93 en_US
dc.identifier.issn 1088-1913
dc.identifier.issue 1 en_US
dc.identifier.startpage 79 en_US
dc.identifier.uri https://doi.org/10.1002/tqem.22020
dc.identifier.uri https://hdl.handle.net/20.500.12573/2053
dc.identifier.volume 33 en_US
dc.language.iso eng en_US
dc.publisher WILEY en_US
dc.relation.isversionof 10.1002/tqem.22020 en_US
dc.relation.journal Environmental Quality Management en_US
dc.relation.publicationcategory Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı en_US
dc.rights info:eu-repo/semantics/closedAccess en_US
dc.subject bubble column reactor en_US
dc.subject carbon dioxide absorption en_US
dc.subject mass transfer coefficient en_US
dc.subject process optimization en_US
dc.subject response surface methodology en_US
dc.title Optimization of carbon dioxide absorption in a continuous bubble column reactor using response surface methodology en_US
dc.type article en_US

Files

Original bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
Environmental Quality Mgmt - 2023 - Gul - Optimization of carbon dioxide absorption in a continuous bubble column reactor.pdf
Size:
6.81 MB
Format:
Adobe Portable Document Format
Description:
Makale Dosyası

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.44 KB
Format:
Item-specific license agreed upon to submission
Description: