Kanser Teşhis ve Tedavisi için Düşük Dozda BT Görüntüleme

dc.contributor.advisor Yılmaz, Bülent
dc.contributor.advisor Yıldırım, İsa
dc.contributor.author SÜMER, ESRA
dc.contributor.author Sümer, Esra
dc.contributor.department AGÜ, Fen Bilimleri Enstitüsü, Elektrik ve Bilgisayar Mühendisliği Ana Bilim Dalı en_US
dc.contributor.institutionauthor SÜMER, ESRA
dc.contributor.other 01. Abdullah Gül University
dc.date.accessioned 2020-07-21T13:00:59Z
dc.date.available 2020-07-21T13:00:59Z
dc.date.issued 2018 en_US
dc.date.issued 2018
dc.description.abstract Kanser, insanlarda sıkça görülen ve ölüm sebepleri arasında ikinci sırada olan bir hastalıktır. Kanserin erken evrelerde teşhis edilmesinin tedavinin başarısını arttırmak için çok kritik olduğu bilinmektedir. Kanserin teşhisi ve evresinin belirlenmesinde farklı görüntüleme yöntemleri kullanılır. Bu yöntemlerden biri bilgisayarlı tomografi (BT), nesnenin etrafından alınan iz düşümleri kullanarak üç boyutlu (3B) nesnenin iki boyutlu (2B) görüntü dilimlerini sağlar. BT'nin temel kısıtları radyasyon dozu ve düşük kontrast duyarlılığıdır. Öncelikle, BT'de radyasyon dozunu azaltmak için daha az sayıda iz düşüm alınabilir ki bu durum geri çatma probleminin eksik belirtili olmasına neden olur. Önceki çalışmalar bu problemi aşmak için yinelemeli geri çatma yöntemleri önermiştir. Bu yöntemlerin en önemli zayıflığı, yüksek hesaplama maliyetidir. Bu sorun toplam değişinti (Total Variation: TV) en küçüklenmesini kullananarak, hesaplama açısından verimli filtrelenmiş geri projeksiyon (filtered backprojection: FBP) temelli yöntem ile ele alınmıştır. 2B modifiye Shepp-Logan fantomu önerilen methodun performans değerlendirmeleri için kullanılmıştır. Önerilen yöntemin üstünlüğü niceliksel ve niteliksel ölçütlerle gösterilmektedir. Tezin ikinci amacı, İstanbul Teknik Üniversitesi Makine Fakültesinde üretilen manyetik nanopartiküllerin (Magnetic Nanoparticles: MNPs) kontrast maddesi olarak kullanarak BT'nin kontrast duyarlılığını arttırılmasıdır. Agaroz jel içindeki beş farklı çekirdekli manyetik nanopartiküllerden kaynaklı piksel yoğunluğu artırımları analiz edilmiştir. Sonuçlar manyetik nanopartiküllerin BT için kontrast madde olarak kullanılabilirliğini doğrulamaktadır.
dc.description.abstract Cancer is a common disease among human population and second leading cause of death. It is well known that diagnosing cancer at early stages is very critical for increasing success of therapy. There have been different imaging modalities used in diagnosing and staging of cancer. One of them is computed tomography (CT) that provides two-dimensional (2D) slices of three-dimensional (3D) object using the series of projections taken around the object. The main limitations of CT are radiation dose and low sensitivity to soft tissue. Firstly, fewer projections can be used to lower dose in CT which causes the reconstruction problem heavily underdetermined. Former studies proposed iterative reconstruction techniques to overcome this problem. The significant weakness of these methods is their computational expensiveness. In the present thesis, this problem is addressed by developing a computationally efficient filtered back projection (FBP) based method using total variation (TV) minimization. 2D modified Shepp-Logan phantom is used for performance evaluations. The superiority of the proposed method is shown both qualitatively and quantitatively. The second aim of the thesis is to enhance contrast capability of CT imaging by using novel magnetic nanoparticles (MNPs) as contrast agents which were fabricated at Mechanical Engineering Department of Istanbul Technical University. The pixel density enhancements of CT images induced by five different core types of MNPs in the agarose gel are analyzed. The results confirm the effectiveness of the MNPs as contrast media for CT imaging. en_US
dc.identifier.other Tez No: 513892
dc.identifier.uri https://hdl.handle.net/20.500.12573/313
dc.identifier.uri https://tez.yok.gov.tr/UlusalTezMerkezi/TezGoster?key=hcgrYffRbz0Z44UJEuLtwb2sgBBgSaavJll6w7xMIBWsqEMzi9oqbXQ0DA4GFH7R
dc.language.iso eng en_US
dc.language.iso en
dc.publisher Abdullah Gül Üniversitesi en_US
dc.rights info:eu-repo/semantics/openAccess en_US
dc.subject Electrical And Electronics Engineering en_US
dc.subject Elektrik Ve Elektronik Mühendisliği
dc.title Kanser Teşhis ve Tedavisi için Düşük Dozda BT Görüntüleme
dc.title Low Dose CT Imaging for Cancer Diagnosis and Therapy en_US
dc.title.alternative Kanser teşhis ve tedavisi için düşük dozda BT görüntüleme en_US
dc.type Master Thesis en_US
dspace.entity.type Publication
gdc.description.department Fen Bilimleri Enstitüsü / Elektrik ve Bilgisayar Mühendisliği Ana Bilim Dalı
gdc.description.endpage 105
gdc.description.publicationcategory Tez en_US
gdc.identifier.yoktezid 513892
relation.isOrgUnitOfPublication 665d3039-05f8-4a25-9a3c-b9550bffecef
relation.isOrgUnitOfPublication.latestForDiscovery 665d3039-05f8-4a25-9a3c-b9550bffecef

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
LOW DOSE CT IMAGING FOR CANCER.pdf
Size:
3.22 MB
Format:
Adobe Portable Document Format
Description:
Yüksek Lisans Tezi

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: