Microfluidic Chip Based Direct Triple Antibody Immunoassay for Monitoring Patient Comparative Response to Leukemia Treatment

Loading...
Publication Logo

Date

2020

Journal Title

Journal ISSN

Volume Title

Publisher

Springer

Open Access Color

Green Open Access

Yes

OpenAIRE Downloads

140

OpenAIRE Views

128

Publicly Funded

No
Impulse
Top 10%
Influence
Average
Popularity
Top 10%

Research Projects

Journal Issue

Abstract

We report a time and cost-efficient microfluidic chip for screening the leukemia cells having three specific antigens. In this method, the target blast cells are double sorted with immunomagnetic beads and captured by the 3rd antibody immobilized on the gold surface in a microfluidic chip. The captured blast cells in the chip were imaged using a bright-field optical microscope and images were analyzed to quantify the cells. First sorting was performed with nano size immunomagnetic beads and followed by 2nd sorting where micron size immunomagnetic beads were used. The low-cost microfluidic platform is made of PMMA and glass including micro size gold pads. The developed microfluidic platform was optimized with cultured B type lymphoblast cells and tested with the samples of leukemia patients. The 8 bone marrow samples of 4 leukemia patients on the initial diagnosis and on the 15th day after the start of the chemotherapy treatment were tested both with the developed microfluidic platform and the flow cytometry. A 99% statistical agreement between the two methods shows that the microfluidic chip is able to monitor the decrease in the number of blast cells due to the chemotherapy. The experiments with the patient samples demonstrate that the developed system can perform relative measurements and have a potential to monitor the patient response to the applied therapy and to enable personalized dose adjustment.

Description

Icoz, Kutay/0000-0002-0947-6166; Akar, Unal/0000-0002-0000-8999;

Keywords

Magnetic Micro, Nano Particles, Immunoassay, Biochip, Leukemia, Direct Triple Antibody, Microfluidic -Based Monitoring, Comparative Response, Immunoassay, Leukemia, Immunomagnetic Separation, nano particles, Direct triple antibody, Magnetic micro, comparative response, Flow Cytometry, Antibodies, Biochip, Treatment Outcome, Lab-On-A-Chip Devices, Humans, Polymethyl Methacrylate, Glass, Microfluidic -based monitoring

Fields of Science

0301 basic medicine, 0303 health sciences, 03 medical and health sciences

Citation

WoS Q

Q2

Scopus Q

Q2
OpenCitations Logo
OpenCitations Citation Count
17

Source

Biomedical Microdevices

Volume

22

Issue

3

Start Page

End Page

PlumX Metrics
Citations

CrossRef : 4

Scopus : 18

PubMed : 4

Captures

Mendeley Readers : 25

Google Scholar Logo
Google Scholar™
OpenAlex Logo
OpenAlex FWCI
0.8583

Sustainable Development Goals

3

GOOD HEALTH AND WELL-BEING
GOOD HEALTH AND WELL-BEING Logo