Eccentricity faults in electric machines remain a critical concern, as they generate uneven magnetic forces that increase vibration and noise, ultimately raising the risk of premature motor failure. This study proposes a method for the early detection of dynamic eccentricity (DE) faults in hydropower plants through an advanced optimization-based parameter identification technique integrated with finite element analysis (FEA). Finite element modeling (FEM) is first used to analyze an existing salient-pole synchronous generator (SPSG) from a hydroelectric power plant in T & uuml;rkiye. The effects of DE faults on the SPSG's magnetic equivalent circuit parameters are then examined under various fault severities. A comprehensive hydropower plant model-including the synchronous generator, governor, and excitation system-is developed in MATLAB/Simulink, with all input parameters obtained from real plant data and equivalent circuit variations extracted from FEA. After completing the modeling stage, including fault scenarios, MATLAB and Simulink are employed together to estimate key magnetic equivalent circuit parameters using a modified particle swarm optimization (MPSO) algorithm, achieving highly accurate parameter estimation. Since the hydropower system allows measurement of the three-phase output currents, parameter estimation is performed based on current variations under different fault conditions. The simulation results verify the method's ability to detect faults with high accuracy; thus, this integrated and noninvasive approach provides a robust framework for ensuring the operational reliability and longevity of large hydro generators.

Description

Keywords

Salient Pole Synchronous Generator (SPSG), Parameter Identification, Condition Monitoring, Fault Detection, Finite Element Modeling (FEM)

Fields of Science

Citation

WoS Q

Q3

Scopus Q

Q2
OpenCitations Logo
OpenCitations Citation Count
N/A

Source

Turkish Journal of Electrical Engineering and Computer Sciences

Volume

34

Issue

1

Start Page

67

End Page

83
PlumX Metrics
Citations

Scopus : 0

Google Scholar Logo
Google Scholar™
OpenAlex Logo
OpenAlex FWCI
0.0

Sustainable Development Goals

SDG data could not be loaded because of an error. Please refresh the page or try again later.