    Thermosensitive Pluronic® F127-Based in Situ Gel Formulation Containing Nanoparticles for the Sustained Delivery of Paclitaxel
    (2023) Unal, Sedat; Aktas, Yesim; Doğan, Osman; Tekeli, Merve Celik
    Bone metastasis is one of the most encountered complications among cancer patients and majority of cancer types has led to bone metastasis. Paclitaxel (PCX) is an anticancer agent commonly used in cancer treatment. However, its clinical use is restricted owing to poor water solubility. PCL NPs were investigated to cope with solubility problem of PCX. The size, polydispersity index and zeta potential of PCL were 383.8±2.4 nm, 0.253±0.122 and +51.3±6.1 mV, respectively. The PCX encapsulation efficiency was 77.2±2.1%. Subsequently, in situ gellling system was prepared by using different Pluronic F-127 concentration in order to determine the optimum ratio. İn situ gel formulation containing 20% Pluronic F-127 was selected as the optimum formulation and subjected to characterization tests. The viscosity of in situ gelling system with CS/PCX-PCL NPs at room temperature (25 °C±0.1) and at body temperature (37 °C±0.1) were found 137.00 ±3.05 cP and 890.30 ±89.61 cP at 100 rpm, respectively. According to the release results, in situ gel provided prolonged release profile compared to PCL NPs alone. Consequently, in situ gel containing CS/PCX-PCL NP elucidated in detail is a promising approach for locally applicable injectable systems.
  • Article
    Citation - WoS: 4
    Citation - Scopus: 4
    All-Polymer Ultrasonic Transducer Design for an Intravascular Ultrasonography Application
    (Tubitak Scientific & Technological Research Council Turkey, 2019-07-26) Hah, Dooyoung
    Intravascular ultrasonography (IVUS), a medical imaging modality, is used to obtain cross-sectional views of blood vessels from inside. In IVUS, transducers are brought to the proximity of the imaging targets so that high-resolution images can be obtained at high frequency without much concern of signal attenuation. To eliminate mechanical rotation rendered in conventional IVUS, it is proposed to manufacture a transducer array on a flexible substrate and wrap it around a cylindrical frame. The transducer of consideration is a capacitive micromachined ultrasonic transducer (CMUT). The whole device needs to be made out of polymers to be able to endure a high degree of bending (radius: 1 mm) Bending of the devices leads to considerable changes in the device characteristics, including resonant frequency and pull-in voltage due to geometrical dimension changes and stress induced. The main purpose of this work is to understand the effect of bending on the device characteristics by means of finite element analysis. Another objective of the work is to understand the relationships between such an effect and the device geometries. It is learned that the bending-induced stress depends strongly on anchor width, membrane thickness, and substrate thickness. It is also learned that resonant frequency and pull-in voltage become lower in most cases because of using a flexible substrate in comparison to those of the device on a rigid substrate. Bending-induced stress increases the spring constant and hence increases resonant frequency and pull-in voltage, although this effect is relatively weaker. For most of the device geometries, pull-in voltage is too high for the polymer material to endure. This is the main drawback of the all-polymer CMUT. In order to meet the design goal of 20 MHz resonant frequency, the membrane radius has to be smaller than 7.7 mu m for a thickness of 3 mu m.