TR-Dizin İndeksli Yayınlar Koleksiyonu
Permanent URI for this collectionhttps://hdl.handle.net/20.500.12573/396
Browse
5 results
Search Results
Article Thermal Stresses in SOFC Stacks: The Role of Mismatch Among Thermal Conductivity of Adjacent Components(Tubitak Scientific & Technological Research Council Turkey, 2021-06-30) Aydin, Ozgur; Matsumoto, Go; Shiratori, YusukeGenerating power from renewable biogas in solid oxide fuel cells (SOFCs) is an environment-friendly, efficient, and promising energy conversion process. Biogas can be used in SOFCs via a reforming process for which dry reforming is more suitable as the reforming agent exists in the biogas mixture. Biogas can be directly reformed to H-2 -rich fuel stream in the anode chamber of a SOFC by the heat released during power generation. Exploiting the heat and water produced in the SOFC for internal reforming of biogas makes the energy conversion process very efficient; however, various challenges are reported. Thus, indirect internal reforming is opted for which a separate reforming domain is required. In an indirect internal reformer operating at usual conditions, dry reforming rate is quite high in the inlet and it decreases steeply toward the fuel outlet. Great temperature gradients develop over the reformer, since the dry reforming reaction is strongly endothermic. The abruptly varying rate of the reforming reaction affects the temperature fields in the adjacent components of SOFC and hence intolerable thermal stresses emerge on the SOFC components. In our preceding study, we graded the reforming domain, homogenized the temperature profile over the reforming domain, and executed performance and durability experiments. However, most of the experiments failed due to fracturing SOFC components hinting at existence of thermal stresses. In that study, we focused on minimizing the temperature gradients within the reforming domain; namely, we neglected the other processes. To eliminate the thermal stresses, we modeled the entire module of SOFC equipped with a reformer featuring a graded reforming domain. We found that the mismatch between the thermal conductivities of the adjacent module components is the major reason for the thermal stresses. When the mismatch is eliminated, thermal stresses disappear even if the reforming domain is not graded.Article Optimizing Parameters for Efficient Computation With Fully Homomorphic Encryption Schemes(Tubitak Scientific & Technological Research Council Turkey, 2025-03-21) Karaagac, Cavidan Yakupoglu; Rohloff, Kurt; Yakupoğlu Karaağaç, Cavidan; Yakupoglu, CavidanIn this study, we aim to provide a parameter selection approach for the BFVrns scheme, one of the prominent fully homomorphic encryption (FHE) schemes. Selecting parameters for lattice-based FHE schemes poses a practical challenge for both experts and nonexperts. To solve this problem, we introduce a hybrid approach that combines theoretical approach with experimental analysis. First, we employ regression analysis to examine the impact of parameters on both performance and security. The varying behavior of FHE parameters in terms of performance, security, and ciphertext expansion factor (CEF) makes parameter selection more challenging. To address this issue, we employ a multi-objective optimization algorithm to determine the optimal parameter set for performance, CEF, and security simultaneously. As a result of this optimization, we obtain an improved parameter set that enhances performance at a given security level while ensuring correctness and resistance to lattice-based attacks, maintaining at least 128-bit security. Our results achieve an average similar to 5x reduction in CEF and generally better performance compared to the parameter sets in a previous BFVrns study. Our approach serves as a semi-automated parameter selection method for the PALISADE homomorphic encryption library, a widely recognized FHE library. This study sets a precedent for other FHE libraries.Article Citation - WoS: 2Citation - Scopus: 2Analysis of Optical Gyroscopes With Vertically Stacked Ring Resonators(Tubitak Scientific & Technological Research Council Turkey, 2021-05-31) Hah, DooyoungWithout any moving part, optical gyroscopes exhibit superior reliability and accuracy in comparison to mechanical sensors. Microring-resonator-based optical gyroscopes emerged as alternatives for bulky conventional Sagnac interferometer sensors, especially attractive for applications with limited footprints. Previously, it has been reported that planar incorporation of multiple resonators does not bring about improvement in sensitivity for a given area because the increase in Sagnac phase accumulation does not outrun the increase of area. Therefore, it was naturally suggested to consider vertical stacking of ring resonators because then, the resonators can share the same footprint. In this work, sensitivity performances of such configurations with vertically stacked microring resonators are analyzed and compared to that of a basic (single-resonator) configuration. Through comprehensive study, it is learned that the sensitivity performance of the devices with vertically-stacked resonators (either with a single bus waveguide or with two bus waveguides) does not exceed that of the basic sensor device (single resonator with one bus waveguide), i.e. the basic structure is yet to be remained as the most efficient configuration.Article Citation - WoS: 2Citation - Scopus: 3An Asymptotic-Numerical Hybrid Method for Singularly Perturbed System of Two-Point Reaction-Diffusion Boundary-Value Problems(Tubitak Scientific & Technological Research Council Turkey, 2019-01-18) Cengizci, Suleyman; Natesan, Srinivasan; Atay, Mehmet TankThis article focuses on the numerical approximate solution of singularly perturbed systems of second-order reaction-diffusion two-point boundary-value problems for ordinary differential equations. To handle these types of problems, a numerical-asymptotic hybrid method has been used. In this hybrid approach, an efficient asymptotic method, the so-called successive complementary expansion method (SCEM) is employed first, and then a numerical method based on finite differences is applied to approximate the solution of corresponding singularly perturbed reaction-diffusion systems. Two illustrative examples are provided to demonstrate the efficiency, robustness, and easy applicability of the present method with convergence properties.Article Citation - WoS: 4Citation - Scopus: 4All-Polymer Ultrasonic Transducer Design for an Intravascular Ultrasonography Application(Tubitak Scientific & Technological Research Council Turkey, 2019-07-26) Hah, DooyoungIntravascular ultrasonography (IVUS), a medical imaging modality, is used to obtain cross-sectional views of blood vessels from inside. In IVUS, transducers are brought to the proximity of the imaging targets so that high-resolution images can be obtained at high frequency without much concern of signal attenuation. To eliminate mechanical rotation rendered in conventional IVUS, it is proposed to manufacture a transducer array on a flexible substrate and wrap it around a cylindrical frame. The transducer of consideration is a capacitive micromachined ultrasonic transducer (CMUT). The whole device needs to be made out of polymers to be able to endure a high degree of bending (radius: 1 mm) Bending of the devices leads to considerable changes in the device characteristics, including resonant frequency and pull-in voltage due to geometrical dimension changes and stress induced. The main purpose of this work is to understand the effect of bending on the device characteristics by means of finite element analysis. Another objective of the work is to understand the relationships between such an effect and the device geometries. It is learned that the bending-induced stress depends strongly on anchor width, membrane thickness, and substrate thickness. It is also learned that resonant frequency and pull-in voltage become lower in most cases because of using a flexible substrate in comparison to those of the device on a rigid substrate. Bending-induced stress increases the spring constant and hence increases resonant frequency and pull-in voltage, although this effect is relatively weaker. For most of the device geometries, pull-in voltage is too high for the polymer material to endure. This is the main drawback of the all-polymer CMUT. In order to meet the design goal of 20 MHz resonant frequency, the membrane radius has to be smaller than 7.7 mu m for a thickness of 3 mu m.