Effect of hydrogen on fracture locus of Fe-16Mn-0.6C-2.15Al TWIP steel

dc.contributor.author Bal, Burak
dc.contributor.author Cetin, Baris
dc.contributor.author Bayram, Ferdi Caner
dc.contributor.author Billur, Eren
dc.contributor.department AGÜ, Mühendislik Fakültesi, Makine Mühendisliği Bölümü en_US
dc.date.accessioned 2021-01-25T08:44:11Z
dc.date.available 2021-01-25T08:44:11Z
dc.date.issued 2020 en_US
dc.description The authors would like to acknowledge Asst. Prof. Dr. Hu seyin Kurtuldu from Baskent University for taking part in the preparation of Python script. The grain size measurement was conducted by means of Automet software which was developed PSARON HTI company. The authors also thank to Psaron company for the use of their software facilities. The authors acknowledge the support by the Scientific and Technological Research Council of Turkey (TU<spacing diaeresis> B_ ITAK, Project No: 118M448). en_US
dc.description.abstract Effect of hydrogen on the mechanical response and fracture locus of commercial TWIP steel was investigated comprehensively by tensile testing TWIP steel samples at room temperature and quasi-static regime. 5 different sample geometries were utilized to ensure different specific stress states and a digital image correlation (DIC) system was used during tensile tests. Electrochemical charging method was utilized for hydrogen charging and microstructural characterizations were carried out by scanning electron microscope. Stress triaxiality factors were calculated throughout the plastic deformation via finite element analysis (FEA) based simulations and average values were calculated at the most critical node. A specific Python script was developed to determine the equivalent fracture strain. Based on the experimental and numerical results, the relation between the equivalent fracture strain and stress triaxiality was determined and the effect of hydrogen on the corresponding fracture locus was quantified. The deterioration in the mechanical response due to hydrogen was observed regardless of the sample geometry and hydrogen changed the fracture mode from ductile to brittle. Moreover, hydrogen affected the fracture locus of TWIP steel by lowering the equivalent failure strains at given stress triaxiality levels. In this study, a modified Johnson-Cook failure mode was proposed and effect of hydrogen on damage constants were quantified. (C) 2020 Hydrogen Energy Publications LLC. Published by Elsevier Ltd. All rights reserved. en_US
dc.description.sponsorship Turkiye Bilimsel ve Teknolojik Arastirma Kurumu (TUBITAK) 118M448 en_US
dc.identifier.endpage 34240 en_US
dc.identifier.issn 0360-3199
dc.identifier.issn 1879-3487
dc.identifier.issue 58 en_US
dc.identifier.startpage 34227 en_US
dc.identifier.uri https://doi.org/10.1016/j.ijhydene.2020.09.083
dc.identifier.uri https://hdl.handle.net/20.500.12573/472
dc.identifier.volume Volume: 45 en_US
dc.language.iso eng en_US
dc.publisher PERGAMON-ELSEVIER SCIENCE LTD, THE BOULEVARD, LANGFORD LANE, KIDLINGTON, OXFORD OX5 1GB, ENGLAND en_US
dc.relation.isversionof 10.1016/j.ijhydene.2020.09.083 en_US
dc.relation.journal INTERNATIONAL JOURNAL OF HYDROGEN ENERGY en_US
dc.relation.publicationcategory Makale - Uluslararası - Editör Denetimli Dergi en_US
dc.relation.tubitak 118M448
dc.rights info:eu-repo/semantics/closedAccess en_US
dc.subject Hydrogen embrittlement en_US
dc.subject Tensile test en_US
dc.subject Fracture locus en_US
dc.subject TWIP steel en_US
dc.subject Johnson-cook failure model en_US
dc.title Effect of hydrogen on fracture locus of Fe-16Mn-0.6C-2.15Al TWIP steel en_US
dc.type article en_US

Files

Original bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
Effect of hydrogen on fracture locus of Fe-16Mn-0.6C-2.15Al TWIP steel.pdf
Size:
3.72 MB
Format:
Adobe Portable Document Format
Description:
Makale dosyası

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.44 KB
Format:
Item-specific license agreed upon to submission
Description: