A New Efficient Error Control Algorithm for Wireless Sensor Networks in Smart Grid

Loading...
Publication Logo

Date

2019

Journal Title

Journal ISSN

Volume Title

Publisher

Elsevier Science Bv

Open Access Color

Green Open Access

No

OpenAIRE Downloads

OpenAIRE Views

Publicly Funded

No
Impulse
Top 10%
Influence
Top 10%
Popularity
Top 10%

Research Projects

Journal Issue

Abstract

Error detection and correction is an important issue in the design and maintenance of a smart grid communication network to provide reliable communication between sender and receiver. Various error-control coding techniques are employed to reduce bit error rates (BER) in wireless sensor networks (WSNs). The performance of these techniques is also compared and evaluated to find the most suitable technique for WSNs. This is the first study to compare the most efficient coding techniques in the smart grid environment, and it suggests a new error correction algorithm based on this comparison result. Therefore, this article first examines and compares two forward error control (FEC) coding techniques such as Bose-Chaudhuri-Hochquenghem code (BCH) and Reed Solomon code (RS) with various modulation methods including frequency shift keying (FSK), offset quadrature phase-shift keying (OQPSK), and differential phase shift keying (DPSK) in a 500 kV line-of-sight (LoS) substation smart grid environment. Second, as a result of this comparison, a new adaptive error control (AEC) algorithm is proposed. Adaptive error control adaptively changes error correction code (ECC) based on the channel behavior that is observed through the packet error rate (PER) in the recent previous transmissions. The link-quality-aware capacitated minimum hop spanning tree (LQ-CMST) algorithm and the multi-channel scheduling algorithm are used for data transmission over the log-normal channel. Therefore, the performance of compared coding techniques and AEC are also evaluated when multiple channels are used during transmission Further, AEC is compared with static RS and without-FEC methods based on performance metrics such as the throughput, BER, and delay in different smart grid environments, e.g., 500 kV Substation (LoS), underground network transformer vaults (UTV) (LoS), and main power control room (MPR) (LoS). Our simulation results indicate that the proposed AEC algorithm achieves better performances than all those techniques.

Description

Yigit, Melike/0000-0002-1275-792X; Sarisaray Boluk, Pinar/0000-0001-8274-8423;

Keywords

Error Detection and Correction, Rs Code, Bch Code, Smart Grid, Multi-Channel Scheduling, AEC

Fields of Science

0202 electrical engineering, electronic engineering, information engineering, 02 engineering and technology

Citation

WoS Q

Q2

Scopus Q

Q1
OpenCitations Logo
OpenCitations Citation Count
19

Source

Computer Standards & Interfaces

Volume

63

Issue

Start Page

27

End Page

42
PlumX Metrics
Citations

Scopus : 26

Captures

Mendeley Readers : 20

SCOPUS™ Citations

26

checked on Apr 18, 2026

Web of Science™ Citations

19

checked on Apr 18, 2026

Page Views

2

checked on Apr 18, 2026

Downloads

3

checked on Apr 18, 2026

Google Scholar Logo
Google Scholar™
OpenAlex Logo
OpenAlex FWCI
2.575

Sustainable Development Goals

SDG data is not available