A New Efficient Error Control Algorithm for Wireless Sensor Networks in Smart Grid
Loading...
Date
2019
Journal Title
Journal ISSN
Volume Title
Publisher
Elsevier Science Bv
Open Access Color
Green Open Access
No
OpenAIRE Downloads
OpenAIRE Views
Publicly Funded
No
Abstract
Error detection and correction is an important issue in the design and maintenance of a smart grid communication network to provide reliable communication between sender and receiver. Various error-control coding techniques are employed to reduce bit error rates (BER) in wireless sensor networks (WSNs). The performance of these techniques is also compared and evaluated to find the most suitable technique for WSNs. This is the first study to compare the most efficient coding techniques in the smart grid environment, and it suggests a new error correction algorithm based on this comparison result. Therefore, this article first examines and compares two forward error control (FEC) coding techniques such as Bose-Chaudhuri-Hochquenghem code (BCH) and Reed Solomon code (RS) with various modulation methods including frequency shift keying (FSK), offset quadrature phase-shift keying (OQPSK), and differential phase shift keying (DPSK) in a 500 kV line-of-sight (LoS) substation smart grid environment. Second, as a result of this comparison, a new adaptive error control (AEC) algorithm is proposed. Adaptive error control adaptively changes error correction code (ECC) based on the channel behavior that is observed through the packet error rate (PER) in the recent previous transmissions. The link-quality-aware capacitated minimum hop spanning tree (LQ-CMST) algorithm and the multi-channel scheduling algorithm are used for data transmission over the log-normal channel. Therefore, the performance of compared coding techniques and AEC are also evaluated when multiple channels are used during transmission Further, AEC is compared with static RS and without-FEC methods based on performance metrics such as the throughput, BER, and delay in different smart grid environments, e.g., 500 kV Substation (LoS), underground network transformer vaults (UTV) (LoS), and main power control room (MPR) (LoS). Our simulation results indicate that the proposed AEC algorithm achieves better performances than all those techniques.
Description
Yigit, Melike/0000-0002-1275-792X; Sarisaray Boluk, Pinar/0000-0001-8274-8423;
Keywords
Error Detection and Correction, Rs Code, Bch Code, Smart Grid, Multi-Channel Scheduling, AEC
Fields of Science
0202 electrical engineering, electronic engineering, information engineering, 02 engineering and technology
Citation
WoS Q
Q2
Scopus Q
Q1

OpenCitations Citation Count
19
Source
Computer Standards & Interfaces
Volume
63
Issue
Start Page
27
End Page
42
PlumX Metrics
Citations
Scopus : 26
Captures
Mendeley Readers : 20
SCOPUS™ Citations
26
checked on Apr 18, 2026
Web of Science™ Citations
19
checked on Apr 18, 2026
Page Views
2
checked on Apr 18, 2026
Downloads
3
checked on Apr 18, 2026
Google Scholar™


