Scopus İndeksli Yayınlar Koleksiyonu
Permanent URI for this collectionhttps://hdl.handle.net/20.500.12573/395
Browse
2 results
Search Results
Conference Object Citation - WoS: 13Citation - Scopus: 15Dynamic Rolling Horizon Control Approach for a University Campus(Elsevier, 2022-04) Yoldas, Yeliz; Goren, Selcuk; Onen, Ahmet; Ustun, Taha SelimAn energy management system based on the rolling horizon control approach has been proposed for the grid-connected dynamic and stochastic microgrid of a university campus in Malta. The aims of the study are to minimize the fuel cost of the diesel generator, minimize the cost of power transfer between the main grid and the micro grid, and minimize the cost of deterioration of the battery to be able to provide optimum economic operation. Since uncertainty in renewable energy sources and load is inevitable, rolling horizon control in the stochastic framework is used to manage uncertainties in the energy management system problem. Both the deterministic and stochastic processes were studied to approve the effectiveness of the algorithm. Also, the results are compared with the Myopic and Mixed Integer Linear Programming algorithms. The results show that the life span of the battery and the associated economic savings are correlated with the SOC values. (c) 2021 The Author(s). Published by Elsevier Ltd.Article Citation - WoS: 12Citation - Scopus: 23Artificial Neural Networks Based Harmonics Estimation for Real University Microgrids Using Hourly Solar Irradiation and Temperature Data(Elsevier, 2023-03) Yarar, Nurcan; Yagci, Mustafa; Bahceci, Serkan; Onen, Ahmet; Ustun, Taha SelimThe need for renewable energy is increasing day by day due to different factors such as increasing energy demand, environmental considerations as well as the will to decrease the share of fossil fuel-based generation. Due to their relative low-cost and ease of installation, PV systems are leading the way for renewable energy deployments around the globe. However, there are meticulous studies that need to be undertaken for realization of such projects. Studying local weather and load patterns for proper panel sizing or considering grid components to determine cable and transformer sizing can be named as some examples for pre-installation studies. In addition to these, post-installation impact studies, e.g. accurate harmonic analysis contribution, is more important to ensure safe and secure operation of the overall system. These steps need to be taken for all PV installation projects. The aim of this study is to show a step-by-step analysis of the effect of a real PV system on the network and to improve the prediction and give a new perspective to the harmonic estimation by using the hourly temperature and radiation data together. At the first phase of the study, a detail real-time 250 kW PV system was modeled for real university campus, and then harmonic estimation based on hourly solar irradiation and hourly temperature was performed with artificial neural networks (ANN) and nonlinear autoregressive exogenous (NARX). The accuracy of the prediction made with ANN was 0.98, and the accuracy of the prediction made with NARX was 0.96.Researchers in PV sizing and control field as well as engineers in power quality area would find these findings beneficial and useful. Use of ANNs and NARX for such analysis indicates the trend in this field that can be targeted by new research projects.
