Scopus İndeksli Yayınlar Koleksiyonu

Permanent URI for this collectionhttps://hdl.handle.net/20.500.12573/395

Browse

Search Results

Now showing 1 - 3 of 3
  • Article
    A Potential Hemostatic Chitosan/Gelatin Cryogel Impregnated with Verbascum Thapsus Leaf Extract for Noncompressible Hemorrhage Management
    (IOP Publishing Ltd, 2025-11-01) Uzuner, Hacernur; Yuruk, Adile; Isoglu, Ismail Alper
    In this study, we prepared a series of chitosan/gelatin (CS/GEL) cryogels containing Verbascum thapsus (V. thapsus) leaf extract and identified a lead formulation for noncompressible hemorrhage (NCH). Cryogels with average pore diameters ranging from 225 to 478 mu m were fabricated through cryogelation at various CS/GEL ratios. C15 was chosen as the base scaffold due to its homogeneous pore distribution, with a pore size coefficient of variation (CV) of approximately 0.22. Extract loading was 1%, 5%, 10%, and 20% w/v. Functional porosity was reported by the relative accessible void index (RAVI). In PBS, the values relative to neat C15 were 1.00, 0.27, 0.20, 0.13, and 0.09 for concentrations of 0%, 1%, 5%, 10%, and 20% w/v, respectively. In citrated blood, the series was 1.00, 0.29, 0.12, 0.14, and 0.09. After loading, equilibrium swelling decreased and the compressive modulus increased, consistent with partial pore filling in a fixed network. The cryogels maintained an interconnected macroporous network and showed swelling from 300% to 3600% in blood and PBS. Antibacterial activity reached 89% inhibition, and cell viability remained above 80%. Hemolysis was low and within acceptance limits. Clotting improved in whole blood as the blood clotting index decreased from 11.9 to 6.5, and the clotting time was approximately 6 min. The 5% w/v group provided the optimal balance of clotting, antibacterial effects, and biocompatibility. This study presents a novel hemostatic CS/GEL cryogel containing V. thapsus leaf extract that holds strong potential for future applications in NCH management.
  • Article
    Tuning Mechanical Performance of PCL Scaffolds: Influence of 3D Bioprinting Parameters, Polymer Concentration, and Solvent Selection
    (IOP Publishing Ltd, 2025-09-01) Ceylan, Saniye Aylin; Baltacioglu, Mehmet Furkan; Bal, Burak; Bayram, Ferdi Caner; Isoglu, Ismail Alper
    The mechanical performance of three-dimensional (3D) bioprinted scaffolds is susceptible to printing parameters and material formulation. In this study, poly (epsilon-caprolactone) (PCL) scaffolds were fabricated using four different polymer concentrations (10%, 25%, 50%, and 75% w/v) to investigate how these variations, along with process parameters, influence mechanical behavior. Maintaining the structural integrity of bioprinted constructs requires careful optimization of polymer concentration and precise control over parameters such as printing speed, pressure, and infill density. Tensile tests were conducted to evaluate the effects of these variables. Among the tested conditions, a 50% (w/v) concentration allowed for a broader operational window, enabling fabrication across a range of printing speeds and pressures. At a printing speed of 5 mm s-1, PCL-DCM exhibited a Young's modulus of 39.0 MPa, while PCL-CF samples printed at 10 mm s-1 achieved the highest modulus of 32.0 MPa. Notably, when the printing speed was kept constant, applying higher pressures led to an increase in Young's modulus, suggesting that pressure plays a key role in enhancing scaffold stiffness. When comparing the 50% and 75% (w/v) polymer concentrations, the 50% (w/v) formulation stood out by offering both higher elongation and greater stiffness, which makes it particularly suitable for load-bearing applications. These findings provide a quantitative framework for optimizing extrusion-based bioprinting of PCL scaffolds, with implications for customized biomedical implants and regenerative medicine.
  • Article
    Citation - WoS: 11
    Citation - Scopus: 13
    On the Detailed Mechanical Response Investigation of PHBV/PCL and PHBV/PLGA Electrospun Mats
    (IOP Publishing Ltd, 2019-03-29) Bal, Burak; Tugluca, Ibrahim Burkay; Koc, Nuray; Isoglu, Ismail Alper
    In this study, electrospun mats of pristine poly(epsilon-caprolactone) (PCL), Poly(D, L-lactide-co-glycolide) (PLGA), poly(3-hydroxybutyrate-co-3-hydroxyvalerate) (PHBV), as well as PHBV/PCL blends and PHBV/PLGA blends in different ratios (80:20, 75:25, 50:50, 25:75, 20:80, 10:90, 5:95%, w/w) and Centella Asiatica (CA) loaded (1, 5, 10%, w/v) PHBV/PCL and PHBV/PLGA polyester blends were prepared. Electrospun mats were characterized by scanning electron microscopy (SEM) in order to show uniform and bead and defect-free fiber structure with average diameter. The blend ratio and strain rate dependencies of mechanical behavior of these electrospun membranes were investigated under tensile loading. The tensile tests were conducted at an initial strain rates of 10(-1) s(-1), 10(-2) s(-1), 10(-3) s(-1) and 10(-4) s(-1) at room temperature and the best and worst combinations of PHBV/PLGA, PHBV/PCL blend ratios for both stress and ductility required applications were specified for each strain rate. The effects of blend ratios on the tensile strength and Young's modulus were also investigated. Moreover, the effects of Centella Asiatica on the electrospun membranes' mechanical behavior were demonstrated at different strain rates. Consequently, this study constitutes an important guideline for the selection and usage of the aforementioned electrospun membranes as a wound dressing material in terms of mechanical response at different loading scenarios.