    Microfluidic Chip Based Direct Triple Antibody Immunoassay for Monitoring Patient Comparative Response to Leukemia Treatment
    (Springer, 2020-07-13) Icoz, Kutay; Akar, Unal; Unal, Ekrem
    We report a time and cost-efficient microfluidic chip for screening the leukemia cells having three specific antigens. In this method, the target blast cells are double sorted with immunomagnetic beads and captured by the 3rd antibody immobilized on the gold surface in a microfluidic chip. The captured blast cells in the chip were imaged using a bright-field optical microscope and images were analyzed to quantify the cells. First sorting was performed with nano size immunomagnetic beads and followed by 2nd sorting where micron size immunomagnetic beads were used. The low-cost microfluidic platform is made of PMMA and glass including micro size gold pads. The developed microfluidic platform was optimized with cultured B type lymphoblast cells and tested with the samples of leukemia patients. The 8 bone marrow samples of 4 leukemia patients on the initial diagnosis and on the 15th day after the start of the chemotherapy treatment were tested both with the developed microfluidic platform and the flow cytometry. A 99% statistical agreement between the two methods shows that the microfluidic chip is able to monitor the decrease in the number of blast cells due to the chemotherapy. The experiments with the patient samples demonstrate that the developed system can perform relative measurements and have a potential to monitor the patient response to the applied therapy and to enable personalized dose adjustment.
  • Article
    Citation - WoS: 14
    Citation - Scopus: 15
    Image-Analysis Based Readout Method for Biochip: Automated Quantification of Immunomagnetic Beads, Micropads and Patient Leukemia Cell
    (Pergamon-Elsevier Science Ltd, 2020-06) Uslu, Fatma; Icoz, Kutay; Tasdemir, Kasim; Dogan, Refika S.; Yilmaz, Bulent
    For diagnosing and monitoring the progress of cancer, detection and quantification of tumor cells is utmost important. Beside standard bench top instruments, several biochip-based methods have been developed for this purpose. Our biochip design incorporates micron size immunomagnetic beads together with micropad arrays, thus requires automated detection and quantification of not only cells but also the micropads and the immunomagnetic beads. The main purpose of the biochip is to capture target cells having different antigens simultaneously. In this proposed study, a digital image processing-based method to quantify the leukemia cells, immunomagnetic beads and micropads was developed as a readout method for the biochip. Color, size-based object detection and object segmentation methods were implemented to detect structures in the images acquired from the biochip by a bright field optical microscope. It has been shown that manual counting and flow cytometry results are in good agreement with the developed automated counting. Average precision is 85 % and average error rate is 13 % for all images of patient samples, average precision is 99 % and average error rate is 1% for cell culture images. With the optimized micropad size, proposed method can reach up to 95 % precision rate for patient samples with an execution time of 90 s per image.