PubMed İndeksli Yayınlar Koleksiyonu
Permanent URI for this collectionhttps://hdl.handle.net/20.500.12573/397
Browse
Browsing PubMed İndeksli Yayınlar Koleksiyonu by Issue Date
Now showing 1 - 20 of 260
- Results Per Page
- Sort Options
Article Magnetic micro/nanoparticle flocculation-based signal amplification for biosensing(DOVE MEDICAL PRESS LTD, PO BOX 300-008, ALBANY, AUCKLAND 0752, NEW ZEALAND, 07.07.2016) Mzava, Omary; Tas, Zehra; Icoz, Kutay; AGÜ, Mühendislik Fakültesi, Elektrik & Elektronik Mühendisliği Bölümü;We report a time and cost efficient signal amplification method for biosensors employing magnetic particles. In this method, magnetic particles in an applied external magnetic field form magnetic dipoles, interact with each other, and accumulate along the magnetic field lines. This magnetic interaction does not need any biomolecular coating for binding and can be controlled with the strength of the applied magnetic field. The accumulation can be used to amplify the corresponding pixel area that is obtained from an image of a single magnetic particle. An application of the method to the Escherichia coli 0157: H7 bacteria samples is demonstrated in order to show the potential of the approach. A minimum of threefold to a maximum of 60-fold amplification is reached from a single bacteria cell under a magnetic field of 20 mT.Article Analysis of coronary angiography related psychophysiological responses(BMC, CAMPUS, 4 CRINAN ST, LONDON N1 9XW, ENGLAND, 2011) Okkesim, Sukru; Kara, Sadik; Kaya, Mehmet G.; Asyali, Musa H.; AGÜ, Mimarlık Fakültesi, Mimarlık Bölümü;Background: Coronary angiography is an important tool in diagnosis of cardiovascular diseases. However, it is the administration is relatively stressful and emotionally traumatic for the subjects. The aim of this study is to evaluate psychophysiological responses induced by the coronary angiography instead of subjective methods such as a questionnaire. We have also evaluated the influence of the tranquilizer on the psychophysiological responses. Methods: Electrocardiography (ECG), Blood Volume Pulse (BVP), and Galvanic Skin Response (GSR) of 34 patients who underwent coronary angiography operation were recorded. Recordings were done at three phases: "1 hour before," "during," and "1 hour after" the coronary angiography test. Total of 5 features obtained from the physiological signals were compared across these three phases. Sixteen of the patients were administered 5 mg of a tranquilizer (Diazepam) before the operation and remaining 18 were not. Results: Our results indicate that there is a strong correlation between features (LF/HF, Bk, DN1/DN2, skin conductance level and seg_mean) in terms of reflecting psychophysiological responses. However only DN1/DN2 feature has statistically significant differences between angiography phases (for diazepam: p = 0.0201, for non_diazepam p = 0.0224). We also note that there are statistically significant differences between the diazepam and non-diazepam groups for seg_mean features in "before", "during" and "after" phases (p = 0.0156, 0.0282, and 0.0443, respectively). Conclusions: The most intense sympathetic activity is observed in the "during" angiography phase for both of the groups. The obtained features can be used in some clinical studies where generation of the customized/individual diagnoses styles and quantitative evaluation of psychophysiological responses is necessary.Article Thermochemistry of alkali metal cation interactions with histidine: Influence of the side chain(American Chemical Society, 2012) Armentrout, P. B.; Citir, Murat; Chen, Yu; Rodgers, M. T.; 0000-0002-7957-110X; AGÜ, Mühendislik Fakültesi, Malzeme Bilimi ve Nanoteknoloji Mühendisliği Bölümü; Citir, MuratThe interactions of alkali metal cations (M+ = Na+ , K+ , Rb+ , Cs+ ) with the amino acid histidine (His) are examined in detail. Experimentally, bond energies are determined using threshold collision-induced dissociation of the M+ (His) complexes with xenon in a guided ion beam tandem mass spectrometer. Analyses of the energy dependent cross sections provide 0 K bond energies of 2.31 ± 0.11, 1.70 ± 0.08, 1.42 ± 0.06, and 1.22 ± 0.06 eV for complexes of His with Na+ , K+ , Rb+ , and Cs+ , respectively. All bond dissociation energy (BDE) determinations include consideration of unimolecular decay rates, internal energy of reactant ions, and multiple ion-neutral collisions. These experimental results are compared to values obtained from quantum chemical calculations conducted previously at the MP2(full)/6-311+G(2d,2p), B3LYP/6-311+G(2d,2p), and B3P86/6-311+G(2d,2p) levels with geometries and zero point energies calculated at the B3LYP/6-311+G(d,p) level where Rb and Cs use the Hay−Wadt effective core potential and basis set augmented with additional polarization functions (HW*). Additional calculations using the def2-TZVPPD basis set with B3LYP geometries were conducted here at all three levels of theory. Either basis set yields similar results for Na+ (His) and K+ (His), which are in reasonable agreement with the experimental BDEs. For Rb+ (His) and Cs+ (His), the HW* basis set and ECP underestimate the experimental BDEs, whereas the def2-TZVPPD basis set yields results in good agreement. The effect of the imidazole side chain on the BDEs is examined by comparing the present results with previous thermochemistry for other amino acids. Both polarizability and the local dipole moment of the side chain are influential in the energetics.Article An FDTD-based computer simulation platform for shock wave propagation in electrohydraulic lithotripsy(ELSEVIER, 2013) Yilmaz, Bulent; Ciftci, Emre; 0000-0003-2954-1217; AGÜ, Mühendislik Fakültesi, Elektrik - Elektronik Mühendisliği Bölümü; Yilmaz, BulentExtracorporeal Shock Wave Lithotripsy (ESWL) is based on disintegration of the kidney stone by delivering high-energy shock waves that are created outside the body and transmitted through the skin and body tissues. Nowadays high-energy shock waves are also used in orthopedic operations and investigated to be used in the treatment of myocardial infarction and cancer. Because of these new application areas novel lithotriptor designs are needed for different kinds of treatment strategies. In this study our aim was to develop a versatile computer simulation environment which would give the device designers working on various medical applications that use shock wave principle a substantial amount of flexibility while testing the effects of new parameters such as reflector size, material properties of the medium, water temperature, and different clinical scenarios. For this purpose, we created a finite-difference time-domain (FDTD)-based computational model in which most of the physical system parameters were defined as an input and/or as a variable in the simulations. We constructed a realistic computational model of a commercial electrohydraulic lithotriptor and optimized our simulation program using the results that were obtained by the manufacturer in an experimental setup. We, then, compared the simulation results with the results from an experimental setup in which oxygen level in water was varied. Finally, we studied the effects of changing the input parameters like ellipsoid size and material,temperature change in the wave propagation media, and shock wave source point misalignment. The simulation results were consistent with the experimental results and expected effects of variation in physical parameters of the system. The results of this study encourage further investigation and provide adequate evidence that the numerical modeling of a shock wave therapy system is feasible and can provide a practical means to test novel ideas in new device design procedures.Article Activation of methane by Os+: Guided-ion-beam and theoretical studies(CHEMM, 2013) Armentrout P.B.; Parke, Laura; Hinton, Christopher; Citir, Murat; 0000-0002-7957-110X; AGÜ, Mühendislik Fakültesi, Malzeme Bilimi ve Nanoteknoloji Mühendisliği Bölümü; Citir, MuratActivation of methane by the third-row transition-metal cation Os + is studied experimentally by examining the kinetic energy dependence of reactions of Os+ with CH4 and CD4 using guided-ion-beam tandem mass spectrometry. A flow tube ion source produces Os+ in its electronic ground state and primarily in the ground spin-orbit level. Dehydrogenation to form [Os,C,2 H]++H2 is exothermic, efficient, and the only process observed at low energies for reaction of Os+ with methane, whereas OsH+ dominates the product spectrum at higher energies. The kinetic energy dependences of the cross sections for several endothermic reactions are analyzed to give 0K bond dissociation energies (in eV) of D0(Os+-C)=6.20±0. 21, D0(Os+-CH)=6.77±0.15, and D0(Os +-CH3)=3.00±0.17. Because it is formed exothermically, D0(Os+-CH2) must be greater than 4.71eV, and a speculative interpretation suggests the exothermicity exceeds 0.6eV. Quantum chemical calculations at the B3LYP/def2-TZVPP level show reasonable agreement with the experimental bond energies and with previous theoretical values available. Theory also provides the electronic structures of the product species as well as intermediates and transition states along the reactive potential energy surfaces. Notably, the structure of the dehydrogenation product is predicted to be HOsCH+, rather than OsCH2+, in contrast to previous work.Article Multiple slow waves and relevant transverse transmission and confinement in chirped photonic crystals(OPTICAL SOC AMER, 2010 MASSACHUSETTS AVE NW, WASHINGTON, DC 20036 USA, 2014) Serebryannikov, Andriy E.; Cakmak, A. Ozgur; Colak, Evrim; Caglayan, Humeyra; Kurt, Hamza; Ozbay, Ekmel; AGÜ, Mühendislik Fakültesi, Elektrik & Elektronik Mühendisliği Bölümü;The dispersion properties of rod-type chirped photonic crystals (PhCs) and non-channeled transmission in the direction of the variation of structural parameters from one cell of such a PhC to another are studied. Two types of configurations that enable multiple slow waves but differ in the utilized chirping scheme are compared. It is demonstrated that the multiple, nearly flat bands with a group index of refraction exceeding 180 can be obtained. For these bands, transmission is characterized by multiple narrow peaks of perfect transmission, strong field enhancement inside the slab, and large values of the Q-factor. Among the bands, there are some that show negative phase velocity. Symmetry with respect to the slab mid-plane must be kept in order to obtain constructive interferences that are necessary for reflection-free transmission. It is shown that 15 and more slow wave bands can be obtained in one configuration. The corresponding transmission peaks are well separated from each other, being the only significant feature of the transmission spectrum, while the Q-factor can exceed 10(5). The observed features are preserved in a wide range of the incidence angle variation. They can be used for tuning the locations and spectral widths of the transmission peaks. Some comparisons with the chirped multilayer structures have been carried out. (C) 2014 Optical Society of AmericaArticle Wireless Measurement of Elastic and Plastic Deformation by a Metamaterial-Based Sensor(MDPI, ST ALBAN-ANLAGE 66, CH-4052 BASEL, SWITZERLAND, 2014) Ozbey, Burak; Demir, Hilmi Volkan; Kurc, Ozgur; Erturk, Vakur B.; Altintas, Ayhan; AGÜ, Mühendislik Fakültesi, Elektrik & Elektronik Mühendisliği Bölümü;We report remote strain and displacement measurement during elastic and plastic deformation using a metamaterial-based wireless and passive sensor. The sensor is made of a comb-like nested split ring resonator (NSRR) probe operating in the near-field of an antenna, which functions as both the transmitter and the receiver. The NSRR probe is fixed on a standard steel reinforcing bar (rebar), and its frequency response is monitored telemetrically by a network analyzer connected to the antenna across the whole stress-strain curve. This wireless measurement includes both the elastic and plastic region deformation together for the first time, where wired technologies, like strain gauges, typically fail to capture. The experiments are further repeated in the presence of a concrete block between the antenna and the probe, and it is shown that the sensing system is capable of functioning through the concrete. The comparison of the wireless sensor measurement with those undertaken using strain gauges and extensometers reveals that the sensor is able to measure both the average strain and the relative displacement on the rebar as a result of the applied force in a considerably accurate way. The performance of the sensor is tested for different types of misalignments that can possibly occur due to the acting force. These results indicate that the metamaterial-based sensor holds great promise for its accurate, robust and wireless measurement of the elastic and plastic deformation of a rebar, providing beneficial information for remote structural health monitoring and post-earthquake damage assessment.Article Colloidal Quantum Dot Light-Emitting Diodes Employing Phosphorescent Small Organic Molecules as Efficient Exciton Harvesters(AMER CHEMICAL SOC, 1155 16TH ST, NW, WASHINGTON, DC 20036 USA, 2014) Mutlugun, Evren; Guzelturk, Burak; Abiyasa, Agus Putu; Gao, Yuan; Sun, Xiao Wei; Demir, Hilmi Volkan; AGÜ, Mühendislik Fakültesi, Elektrik & Elektronik Mühendisliği Bölümü;Nonradiative energy transfer (NRET) is an alternative excitation mechanism in colloidal quantum dot (QD) based electroluminescent devices (QLEDs). Here, we develop hybrid highly spectrally pure QLEDs that facilitate energy transfer pumping via NRET from a phosphorescent small organic molecule-codoped charge transport layer to the adjacent QDs. A partially codoped exciton funnelling electron transport layer is proposed and optimized for enhanced QLED performance while exhibiting very high color purity of 99%. These energy transfer pumped hybrid QLEDs demonstrate a 6-fold enhancement factor in the external quantum efficiency over the conventional QLED structure, in which energy transfer pumping is intrinsically weak.Article Highly Transparent Au-Coated Ag Nanowire Transparent Electrode with Reduction in Haze(AMER CHEMICAL SOC, 2014) Kim, Taegeon; Canlier, Ali; Lee, Jung-Yong; Rozyyev, Vepa; Han, Seung Min; Cho, Changsoon; 0000-0003-2488-1167; AGÜ, Mühendislik Fakültesi, Malzeme Bilimi ve Nanoteknoloji Mühendisliği Bölümü; Canlier, AliAg nanowire transparent electrode has excellent transmittance and sheet resistance, yet its optical haze still needs to be improved in order for it to be suitable for display applications. Ag nanowires are known to have high haze because of the geometry of the nanowire and the high light scattering characteristic of the Ag. In this study, a Au-coated Ag nanowire structure was proposed to reduce the haze, where a thin layer of Au was coated on the surface of the Ag nanowires using a mild [Au(en)2]Cl3 galvanic displacement reaction. The mild galvanic exchange allowed for a thin layer of Au coating on the Ag nanowires with minimal truncation of the nanowire, where the average length and the diameter were 13.0 μm and 60 nm, respectively. The Au-coated Ag nanowires were suspended in methanol and then electrostatically sprayed on a flexible polycarbonate substrate that revealed a clear reduction in haze with a 2–4% increase in total transmittance, sheet resistance ranges of 80–90%, and 8.8–36.8 Ohm/sq. Finite difference time domain simulations were conducted for Au-coated Ag nanowires that indicated a significant reduction in the average scattering from 1 to 0.69 for Au layer thicknesses of 0–10 nm.Article Nanosecond colloidal quantum dot lasers for sensing(OPTICAL SOC AMER, 2010 MASSACHUSETTS AVE NW, WASHINGTON, DC 20036 USA, 2014) Mutlugun, Evren; Guilhabert, B.; Foucher, Caroline; Haughey, Anne-Marie; Gao, Yuan; Herrnsdorf, Johannes; Sun, Han-Dong; Demir, Hilmi Volkan; Dawson, Martin; Laurand, Nicolas; AGÜ, Mühendislik Fakültesi, Elektrik & Elektronik Mühendisliği Bölümü;Low-threshold, gain switched colloidal quantum dot (CQD) distributed-feedback lasers operating in the nanosecond regime are reported and proposed for sensing applications for the first time to the authors' knowledge. The lasers are based on a mechanically-flexible polymeric, second order grating structure overcoated with a thin-film of CQD/PMMA composite. The threshold fluence of the resulting lasers is as low as 0.5 mJ/cm(2) for a 610 nm emission and the typical linewidth is below 0.3 nm. The emission wavelength of the lasers can be set at the design stage and laser operation between 605 nm and 616 nm, while using the exact same CQD gain material, is shown. In addition, the potential of such CQD lasers for refractive index sensing in solution is demonstrated by immersion in water. (C) 2014 Optical Society of AmericaArticle PANOGA: a web server for identification of SNP-targeted pathways from genome-wide association study data(OXFORD UNIV PRESS, GREAT CLARENDON ST, OXFORD OX2 6DP, ENGLAND, 2014) Bakir-Gungor, Burcu; Egemen, Ece; Sezerman, Osman Ugur; AGÜ, Mühendislik Fakültesi, Bilgisayar Mühendisliği Bölümü;Genome-wide association studies (GWAS) have revolutionized the search for the variants underlying human complex diseases. However, in a typical GWAS, only a minority of the single-nucleotide polymorphisms (SNPs) with the strongest evidence of association is explained. One possible reason of complex diseases is the alterations in the activity of several biological pathways. Here we present a web server called Pathway and Network-Oriented GWAS Analysis to devise functionally important pathways through the identification of SNP-targeted genes within these pathways. The strength of our methodology stems from its multidimensional perspective, where we combine evidence from the following five resources: (i) genetic association information obtained through GWAS, (ii) SNP functional information, (iii) protein-protein interaction network, (iv) linkage disequilibrium and (v) biochemical pathways.Article Highly flexible, electrically driven, top-emitting, quantum dot light-emitting stickers(American Chemical Society, 2014) Yang, Xuyong; Mutlugun, Evren; Dang, Cuong; Dev, Kapil; Gao, Yuan; Tan, Swee Tiam; Sun, Xiao Wei; Demir, Hilmi Volkan; 0000-0003-3715-5594; AGÜ, Mühendislik Fakültesi, Elektrik - Elektronik Mühendisliği Bölümü; Mutlugun, EvrenFlexible information displays are key elements in future optoelectronic devices. Quantum dot light-emitting diodes (QLEDs) with advantages in color quality, stability, and cost-effectiveness are emerging as a candidate for single-material, full color light sources. Despite the recent advances in QLED technology, making high-performance flexible QLEDs still remains a big challenge due to limited choices of proper materials and device architectures as well as poor mechanical stability. Here, we show highly efficient, large-area QLED tapes emitting in red, green, and blue (RGB) colors with top-emitting design and polyimide tapes as flexible substrates. The brightness and quantum efficiency are 20 000 cd/m2 and 4.03%, respectively, the highest values reported for flexible QLEDs. Besides the excellent electroluminescence performance, these QLED films are highly flexible and mechanically robust to use as electrically driven light-emitting stickers by placing on or removing from any curved surface, facilitating versatile LED applications. Our QLED tapes present a step toward practical quantum dot based platforms for high-performance flexible displays and solid-state lighting.Article Like/dislike analysis using EEG: Determination of most discriminative channels and frequencies(ELSEVIER IRELAND LTD, 2014) Asyali, Musa H.; Gungor, Evrim; Arslan, Dilek Betul; Korkmaz, Sumeyye; Yilmaz, Bulent; 0000-0003-2954-1217; AGÜ, Mühendislik Fakültesi, Elektrik - Elektronik Mühendisliği Bölümü; Yilmaz, BulentIn this study, we have analyzed electroencephalography (EEG) signals to investigate the following issues, (i) which frequencies and EEG channels could be relatively better indicators of preference (like or dislike decisions) of consumer products, (ii) timing characteristic of "like" decisions during such mental processes. For this purpose, we have obtained multi-channel EEG recordings from 15 subjects, during total of 16 epochs of 10 s long, while they were presented with some shoe photographs. When they liked a specific shoe, they pressed on a button and marked the time of this activity and the particular epoch was labeled as a LIKE case. No button press meant that the subject did not like the particular shoe that was displayed and corresponding epoch designated as a DISLIKE case. After preprocessing, power spectral density (PSD) of EEG data was estimated at different frequencies (4, 5, ... , 40 Hz) using the Burg method, for each epoch corresponding to one shoe presentation. Each subject's data consisted of normalized PSD values (NPVs) from all LIKE and DISLIKE cases/epochs coming from all 19 EEG channels. In order to determine the most discriminative frequencies and channels, we have utilized logistic regression, where LIKE/DISLIKE status was used as a categorical (binary) response variable and corresponding NPVs were the continuously valued input variables or predictors. We observed that when all the NPVs (total of 37) are used as predictors, the regression problem was becoming ill-posed due to large number of predictors (compared to the number of samples) and high correlation among predictors. To circumvent this issue, we have divided the frequency band into low frequency (LF) 4-19 Hz and high frequency (HF) 20-40 Hz bands and analyzed the influence of the NPV in these bands separately. Then, using the p-values that indicate how significantly estimated predictor weights are different than zero, we have determined the NPVs and channels that are more influential in determining the outcome, i. e., like/dislike decision. In the LF band, 4 and 5 Hz were found to be the most discriminative frequencies (MDFs). In the HF band, none of the frequencies seemed offer significant information. When both male and female data was used, in the LF band, a frontal channel on the left (F7-A1) and a temporal channel on the right (T6-A2) were found to be the most discriminative channels (MDCs). In the HF band, MDCs were central (Cz-A1) and occipital on the left (O1-A1) channels. The results of like timings suggest that male and female behavior for this set of stimulant images were similar. (C) 2013 Elsevier Ireland Ltd. All rights reserved.Article Air-stable, nanostructured electronic and plasmonic materials from solution-processable, silver nanocrystal building blocks(American Chemical Society, 2014) Fafarman, Aaron T.; Hong, Sung-Hoon; Oh, Soong Ju; Caglayan, Humeyra; Ye, Xingchen; Diroll, Benjamin T.; Engheta, Nader; Murray, Christopher B.; Kagan, Cherie R.; 0000-0002-0656-614X; AGÜ, Mühendislik Fakültesi, Elektrik - Elektronik Mühendisliği Bölümü; Caglayan, HumeyraHerein we describe a room-temperature, chemical process to transform silver nanocrystal solids, deposited from colloidal solutions, into highly conductive, corrosion-resistant, optical and electronic materials with nanometer-scale architectures. After assembling the nanocrystal solids, we treated them with a set of simple, compact, organic and inorganic reagents: ammonium thiocyanate, ammonium chloride, potassium hydrogen sulfide, and ethanedithiol. We find that each reagent induces unique changes in the structure and composition of the resulting solid, giving rise to films that vary from insulating to, in the case of thiocyanate, conducting with a remarkably low resistivity of 8.8 × 10-6 ·cm, only 6 times that of bulk silver. We show that thiocyanate mediates the spontaneous sintering of nanocrystals into structures with a roughness of less than 1/10th of the wavelength of visible light. We demonstrate that these solution-processed, low-resistivity, optically smooth films can be patterned, using imprint lithography, into conductive electrodes and plasmonic mesostructures with programmable resonances. We observe that thiocyanate-treated solids exhibit significantly retarded atmospheric corrosion, a feature that dramatically increases the feasibility of employing silver for electrical and plasmonic applications.Article Clinical probe utilizing surface enhanced Raman scattering(A V S AMER INST PHYSICS, STE 1 NO 1, 2 HUNTINGTON QUADRANGLE, MELVILLE, NY 11747-4502 USA, 2014) Kim, Jeonghwan; Hah, Dooyoung; Daniels-Race, Theda; Feldman, Martin; AGÜ, Mühendislik Fakültesi, Elektrik & Elektronik Mühendisliği Bölümü;Conventional Raman scattering is a well-known technique for detecting and identifying complex molecular samples. In surface enhanced Raman scattering, a nanorough metallic surface close to the sample enormously enhances the Raman signal. In previous work, the metallic surface was a thin layer of gold deposited on a rough transparent epoxy substrate. The advantage of the clear substrate was that the Raman signal could be obtained by passing light through the substrate, on to opaque samples simply placed against its surface. In this work, a commercially available Raman spectrometer was coupled to a distant probe. Raman signals were obtained from the surface, and from the interior, of a solid specimen located more than 1 m away from the spectrometer. The practical advantage of this arrangement is that it opens up surface enhanced Raman spectrometry to a clinical environment, with a patient simply sitting or lying near the spectrometer. (C) 2014 American Vacuum Society.Article HomSI: a homozygous stretch identifier from next-generation sequencing data(OXFORD UNIV PRESS, GREAT CLARENDON ST, OXFORD OX2 6DP, ENGLAND, 2014) Gormez, Zeliha; Bakir-Gungor, Burcu; Sagiroglu, Mahmut Samil; AGÜ, Mühendislik Fakültesi, Bilgisayar Mühendisliği Bölümü;In consanguineous families, as a result of inheriting the same genomic segments through both parents, the individuals have stretches of their genomes that are homozygous. This situation leads to the prevalence of recessive diseases among the members of these families. Homozygosity mapping is based on this observation, and in consanguineous families, several recessive disease genes have been discovered with the help of this technique. The researchers typically use single nucleotide polymorphism arrays to determine the homozygous regions and then search for the disease gene by sequencing the genes within this candidate disease loci. Recently, the advent of next-generation sequencing enables the concurrent identification of homozygous regions and the detection of mutations relevant for diagnosis, using data from a single sequencing experiment. In this respect, we have developed a novel tool that identifies homozygous regions using deep sequence data. Using*.vcf (variant call format) files as an input file, our program identifies the majority of homozygous regions found by microarray single nucleotide polymorphism genotype data.Article Selective Remanent Ambipolar Charge Transport in Polymeric Field-Effect Transistors For High-Performance Logic Circuits Fabricated in Ambient(WILEY-V C H VERLAG GMBHPOSTFACH 101161, 69451 WEINHEIM, GERMANY, 2014) Fabiano, Simone; Usta, Hakan; Forchheimer, Robert; Crispin, Xavier; Facchetti, Antonio; Berggren, Magnus; 0000-0001-5154-0291; 0000-0001-7016-6514; 0000-0002-0618-1979; 0000-0002-8175-7958; AGÜ, Mühendislik Fakültesi, Malzeme Bilimi ve Nanoteknoloji Mühendisliği Bölümü; Usta, HakanAmbipolar polymeric field-effect transistors can be programmed into a p- or n-type mode by using the remanent polarization of a ferroelectric gate insulator. Due to the remanent polarity, the device architecture is suited as a building block in complementary logic circuits and in CMOS-compatible memory cells for non-destructive read-out operations.Article Development of a Nanoparticle-Embedded Chitosan Sponge for Topical and Local Administration of Chemotherapeutic Agents(American Society of Mechanical Engineers (ASME), 2014) Goldberg, Manijeh; Manzi, Aaron; Aydin, Erkin; Singh, Gurtej; Khoshkenar, Payam; Birdi, Amritpreet; LaPorte, Brandon; Krauskopf, Alejandro; Powell, Geralle; Chen, Julie; Langer, Robert; 0000-0001-7811-2959; AGÜ, Mühendislik Fakültesi, Makine Mühendisliği Bölümü; Aydin, ErkinThe following work describes the development of a novel noninvasive transmucosal drug delivery system, the chitosan sponge matrix (CSM). It is composed of cationic chitosan (CS) nanoparticles (NPs) that encapsulate cisplatin (CDDP) embedded within a polymeric mucoadhesive CS matrix. CSM is designed to swell up when exposed to moisture, facilitating release of the NPs via diffusion across the matrix. CSM is intended to be administered topically and locally to mucosal tissues, with its initial indication being oral cancer (OC). Currently, intravenous (IV) administered CDDP is the gold standard chemotherapeutic agent used in the treatment of OC. However, its clinical use has been limited by its renal and hemotoxicity profile. We aim to locally administer CDDP via encapsulation in CS NPs and deliver them directly to the oral cavity with CSM. It is hypothesized that such a delivery device will greatly reduce any systemic toxicity and increase antitumor efficacy. This paper describes the methods for developing CSM and maintaining the integrity of CDDP NPs embedded in the CSM.Article On Critical Buckling Loads of Columns under End Load Dependent on Direction(Hindawi Publishing Corporation, 2014) Başbük, Musa; Eryılmaz, Aytekin; Atay, Mehmet Tarik; AGÜ, Mühendislik Fakültesi, Makine Mühendisliği Bölümü; Atay, M.TarıkMost of the phenomena of various fields of applied sciences are nonlinear problems. Recently, various types of analytical approximate solution techniques were introduced and successfully applied to the nonlinear differential equations. One of the aforementioned techniques is the Homotopy analysis method (HAM). In this study, we applied HAM to find critical buckling load of a column under end load dependent on direction. We obtained the critical buckling loads and compared them with the exact analytic solutions in the literature.Article On-demand weighing of single dry biological particles over a 5-order-of-magnitude dynamic range(ROYAL SOC CHEMISTRY, 2014) Chan, Bin-Da; Huang, Wanfeng; Chang, Chun-Li; Savran, Cagri A.; Icoz, Kutay; 0000-0002-0947-6166; AGÜ, Mühendislik Fakültesi, Elektrik - Elektronik Mühendisliği Bölümü; Icoz, KutayWe report a simple and highly versatile system to select and weigh individual dry biological particles. The system is composed of a microtweezer to pick and place individual particles and a cantilever-based resonator to weigh them. The system can weigh entities that vary from a red blood cell (~10−11 g) to the eye–brain complex of an insect (~10−6 g), covering a 5-order-of-magnitude mass range. Due to its versatility and ease of use, this weighing method is highly compatible with established laboratory practices. The system can provide complementary mass information for a wide variety of individual particles imaged using scanning electron microscopy and determine comparative weights of individual biological entities that are attached to microparticles as well as weigh fractions of individual biological entities that have been subjected to focused ion beam milling.