Improving sensitivity biosensors by using micro/nano magnetic particles

dc.contributor.author OMARY MUSTAFA, MZAVA
dc.contributor.department AGÜ, Fen Bilimleri Enstitüsü, Elektrik ve Bilgisayar Mühendisliği Ana Bilim Dalı en_US
dc.contributor.institutionauthor OMARY MUSTAFA, MZAVA
dc.date.accessioned 2020-07-21T07:19:52Z
dc.date.available 2020-07-21T07:19:52Z
dc.date.issued 2016 en_US
dc.description.abstract Currently micro/nanoparticles such as magnetic beads are not only used as labels to acquire signals from biosensors but they are also used to enhance the signals obtained from various biosensors. Magnetic beads or target are linked to other molecular labels such as fluorescence and chemiluminescence labels by biomolecules such as antibody to reach higher sensitivity and provide signal amplification for the measurement. This dependency on biomolecular binding has several disadvantages such as molecular binding is sensitive to environmental conditions such as pH and temperature, labels are costly and molecular binding may require extra time. In this thesis a time and cost efficient signal amplification method that does not need any biomolecular coating but based on magnetic interaction of magnetic micro/nanoparticles is developed. Magnetic particles subjected to external magnetic field are magnetized and form a local field around them, attract each other and accumulate along the magnetic field lines. These controlled accumulations can be used to amplify the pixel area or the contrast of magnetic particles. Accumulation dynamics of magnetic particles under magnetic field are studied and the application of this method to the Escherichia coli 0157:H7 sample is demonstrated. Lastly the integration of this signal amplification method to a flow chamber and a complete biosensing procedure is pursued. Magnetic micro/ nano particles that are immobilized on gold-coated surface under external magnetic field inside a flow chamber attract the iron nanoparticles in a running fluid to form chains of accumulations around them. The accumulations formed under magnetic field are used to improve the Contrast to Noise Ratio (CNR) of the images thus the sensitivity. en_US
dc.identifier.other Tez No: 434249
dc.identifier.uri https://hdl.handle.net/20.500.12573/299
dc.language.iso eng en_US
dc.publisher Abdullah Gül Üniversitesi en_US
dc.relation.publicationcategory Tez en_US
dc.rights info:eu-repo/semantics/openAccess en_US
dc.subject magnetic micro/nanoparticle accumulation en_US
dc.subject signal amplification en_US
dc.subject flow chamber en_US
dc.subject magnetic dipole-dipole interaction, en_US
dc.subject biosensor. en_US
dc.title Improving sensitivity biosensors by using micro/nano magnetic particles en_US
dc.title.alternative Mikro/nano manyetik parçacıkları kullanarak biyosensörlerin hassasiyetini iyileştirme en_US
dc.type masterThesis en_US

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
IMPROVING SENSITIVITY OF BIOSENSORS.pdf
Size:
2.9 MB
Format:
Adobe Portable Document Format
Description:
Yüksek lisans Tezi

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: