WoS İndeksli Yayınlar Koleksiyonu

Permanent URI for this collectionhttps://hdl.handle.net/20.500.12573/394

Browse

Search Results

Now showing 1 - 9 of 9
  • Conference Object
    Detection of Variation Instances on Colonoscopy Videos using Structural Similarity Index
    (IEEE, 345 E 47TH ST, NEW YORK, NY 10017 USA, 2018) Kacmaz, Rukiye Nur; Yilmaz, Bulent
    The aim of this study is to reduce the number of images extracted from the videos recorded by the specialists during the colonoscopy process for further examination, thereby enabling the specialist to deal with fewer images. Since the images obtained from the videos are very similar, the main assumption of this study is that the whole video can be represented by fewer images. The approach used in this study is the structural similarity index. Totally, images were obtained from 4 different videos coming from healthy, ulcerative colitis, Crohn's, and polyp patients. The noisy images in these videos were eliminated manually. When the structural similarity index between two consecutive clear images was less than 0.83, the second image was selected and shown to the specialist for his/her examination. By this way, the frames carrying significantly new information from the videos were defined as the variation instances. The tests on healthy or diseased colon videos showed that only 5-10% of the clear images provide significantly new information.
  • Conference Object
    Citation - WoS: 1
    Citation - Scopus: 1
    Polyp Localization in Colonoscopy Images Using Vessel Density
    (Institute of Electrical and Electronics Engineers Inc., 2018-11) Doǧan, Refika Sultan; Yilmaz, Bulent
    In this paper, we present a new approach for polyp localization in colonoscopy images. This approach is based on the determination of the polyp location using the vessel density in colon images. Primarily, we used pre-processing procedures on the colon images, and then blood vessel extraction techniques were employed. Later, segmentation of the vessel boundaries was performed. With the help of vessel boundaries we calculated the vessel density, and used this for the localization of the polyps. We tested the success of this approach using a publicly available image set (CVC-ClinicDB database). This database consisted of 612 images from 29 different polyps. This approach succeeds in correct detection of 24 out of 29 different polyps. © 2019 Elsevier B.V., All rights reserved.
  • Article
    Citation - WoS: 1
    Motion Artifact Detection in Colonoscopy Images
    (Sciendo, 2018-07-01) Kacmaz, Rukiye Nur; Yilmaz, Bulent; Dundar, Mehmet Sait; Dogan, Serkan
    Computer-aided detection is an integral part of medical image evaluation process because examination of each image takes a long time and generally experts' do not have enough time for the elimination of images with motion artifact (blurred images). Computer-aided detection is required for both increasing accuracy rate and saving experts' time. Large intestine does not have straight structure thus camera of the colonoscopy should be moved continuously to examine inside of the large intestine and this movement causes motion artifact on colonoscopy images. In this study, images were selected from open-source colonoscopy videos and obtained at Kayseri Training and Research Hospital. Totally 100 images were analyzed half of which were clear. Firstly, a modified version of histogram equalization was applied in the pre-processing step to all images in our dataset, and then, used Laplacian, wavelet transform (WT), and discrete cosine transform-based (DCT) approaches to extract features for the discrimination of images with no artifact (clear) and images with motion artifact. The Laplacian-based feature extraction method was used for the first time in the literature on colonoscopy images. The comparison between Laplacian-based features and previously used methods such as WT and DCT has been performed. In the classification phase of our study, support vector machines (SVM), linear discriminant analysis (LDA), and k nearest neighbors (k-NN) were used as the classifiers. The results showed that Laplacian-based features were more successful in the detection of images with motion artifact when compared to popular methods used in the literature. As a result, a combination of features extracted using already existing approaches (WT and DCT) and the Laplacian-based methods reached 85% accuracy levels with SVM classification approach.
  • Article
    Citation - WoS: 14
    Citation - Scopus: 15
    Image-Analysis Based Readout Method for Biochip: Automated Quantification of Immunomagnetic Beads, Micropads and Patient Leukemia Cell
    (Pergamon-Elsevier Science Ltd, 2020-06) Uslu, Fatma; Icoz, Kutay; Tasdemir, Kasim; Dogan, Refika S.; Yilmaz, Bulent
    For diagnosing and monitoring the progress of cancer, detection and quantification of tumor cells is utmost important. Beside standard bench top instruments, several biochip-based methods have been developed for this purpose. Our biochip design incorporates micron size immunomagnetic beads together with micropad arrays, thus requires automated detection and quantification of not only cells but also the micropads and the immunomagnetic beads. The main purpose of the biochip is to capture target cells having different antigens simultaneously. In this proposed study, a digital image processing-based method to quantify the leukemia cells, immunomagnetic beads and micropads was developed as a readout method for the biochip. Color, size-based object detection and object segmentation methods were implemented to detect structures in the images acquired from the biochip by a bright field optical microscope. It has been shown that manual counting and flow cytometry results are in good agreement with the developed automated counting. Average precision is 85 % and average error rate is 13 % for all images of patient samples, average precision is 99 % and average error rate is 1% for cell culture images. With the optimized micropad size, proposed method can reach up to 95 % precision rate for patient samples with an execution time of 90 s per image.
  • Article
    Citation - WoS: 15
    Citation - Scopus: 18
    Histopathology Image Classification: Highlighting the Gap Between Manual Analysis and AI Automation
    (Frontiers Media S.A., 2024-01-17) Dogan, Refika Sultan; Yilmaz, Bulent
    The field of histopathological image analysis has evolved significantly with the advent of digital pathology, leading to the development of automated models capable of classifying tissues and structures within diverse pathological images. Artificial intelligence algorithms, such as convolutional neural networks, have shown remarkable capabilities in pathology image analysis tasks, including tumor identification, metastasis detection, and patient prognosis assessment. However, traditional manual analysis methods have generally shown low accuracy in diagnosing colorectal cancer using histopathological images. This study investigates the use of AI in image classification and image analytics using histopathological images using the histogram of oriented gradients method. The study develops an AI-based architecture for image classification using histopathological images, aiming to achieve high performance with less complexity through specific parameters and layers. In this study, we investigate the complicated state of histopathological image classification, explicitly focusing on categorizing nine distinct tissue types. Our research used open-source multi-centered image datasets that included records of 100.000 non-overlapping images from 86 patients for training and 7180 non-overlapping images from 50 patients for testing. The study compares two distinct approaches, training artificial intelligence-based algorithms and manual machine learning models, to automate tissue classification. This research comprises two primary classification tasks: binary classification, distinguishing between normal and tumor tissues, and multi-classification, encompassing nine tissue types, including adipose, background, debris, stroma, lymphocytes, mucus, smooth muscle, normal colon mucosa, and tumor. Our findings show that artificial intelligence-based systems can achieve 0.91 and 0.97 accuracy in binary and multi-class classifications. In comparison, the histogram of directed gradient features and the Random Forest classifier achieved accuracy rates of 0.75 and 0.44 in binary and multi-class classifications, respectively. Our artificial intelligence-based methods are generalizable, allowing them to be integrated into histopathology diagnostics procedures and improve diagnostic accuracy and efficiency. The CNN model outperforms existing machine learning techniques, demonstrating its potential to improve the precision and effectiveness of histopathology image analysis. This research emphasizes the importance of maintaining data consistency and applying normalization methods during the data preparation stage for analysis. It particularly highlights the potential of artificial intelligence to assess histopathological images.
  • Article
    Citation - WoS: 7
    Citation - Scopus: 5
    Effect of Interpolation on Specular Reflections in Texture-Based Automatic Colonic Polyp Detection
    (Wiley, 2020-06-26) Kacmaz, Rukiye Nur; Yilmaz, Bulent; Aydin, Zafer
    Reflections of LED light cause unwanted noise effects called specular reflection (SR) on colonoscopic images. The aim of this study was to seek answers to the following two questions. (a) How are the texture features used in automatic detection of polyps affected by the interpolation on specular reflections? (b) If they are affected does it really affect the classification performance? In order to answer these questions, we used 610 colonoscopy images, and divided each image into tiles whose sizes were 32-by-32 pixels. From these tiles, we selected the ones without any specular reflection. We added different shape and size specular reflections cropped from real images onto the reflection-free tiles. We then used the nearest neighbors, bilinear and bicubic interpolation techniques on the tiles on which SRs were added. On these tiles we extracted 116 texture features using 3 second-order approaches, and 4 first-order statistics. First, we used paired samplettest. Second, we performed automatic classification of polyps and background using random forest and k nearest neighbors (k-NN) approaches using the texture features for different combinations of specular reflections added on the tiles from the polyp or background. The results showed that depending on the size of specular reflection, interpolation can cause a significant difference between the texture features that were coming from reflection-free tiles and the same tiles on which interpolation was performed. In addition, we note that bicubic interpolation may be preferred to eliminate specular reflection when texture features are used for background and polyp discrimination.
  • Conference Object
    Kolonoskopi Görüntülerinde Bilineer İnterpolasyonun Tekstör Analizine Etkisi
    (Institute of Electrical and Electronics Engineers Inc., 2017-10) Kacmaz, Rukiye Nur; Yilmaz, Bulent
    Interpolation is a method that is used to obtain unknown intensities with the help of known intensities on an image. This method is frequently used in the literature to eliminate light reflection on colonoscopy images. Texture features are the most important characteristics used to describe the region or objects of interest in the image. They are the measures of intensity variation of a surface that determine properties such as smoothness, roughness, and regularity. The aim of this study is to find out the how bilinear interpolation applied on colonoscopy images with reflection impact texture features obtained from the same images. A research carried out to make reasonable comparison between a texture feature from an image with no reflection and the same feature obtained from the same image with synthetically added reflections with various percentages. Using the approaches like gray level co-occurence matrix (GLCM), gray level run length matrix (GLRLM), neighborhood gray tone difference matrix (NGTDM) 126 features were extracted from each 32×32 sub-images coming from 610 colonoscopy images. Several of the features extracted from sub-images with no reflection and reflection were not statistically significantly different, while majority of them were affected from the reflections. © 2018 Elsevier B.V., All rights reserved.
  • Conference Object
    Citation - Scopus: 1
    Yapısal Benzerlik İndeksini Kullanarak Kolonoskopi Videolarında Değişim Anlarının Belirlenmesi
    (IEEE, 2018-11) Kacmaz, Rukiye Nur; Yilmaz, Bulent
    The aim of this study is to reduce the number of images extracted from the videos recorded by the specialists during the colonoscopy process for further examination, thereby enabling the specialist to deal with fewer images. Since the images obtained from the videos are very similar, the main assumption of this study is that the whole video can be represented by fewer images. The approach used in this study is the structural similarity index. Totally, images were obtained from 4 different videos coming from healthy, ulcerative colitis, Crohn's, and polyp patients. The noisy images in these videos were eliminated manually. When the structural similarity index between two consecutive clear images was less than 0.83, the second image was selected and shown to the specialist for his/her examination. By this way, the frames carrying significantly new information from the videos were defined as the variation instances. The tests on healthy or diseased colon videos showed that only 5-10% of the clear images provide significantly new information.
  • Conference Object
    Kolonoskopi Görüntülerinden Otomatik Ülseratif Kolit Teşhisi
    (Institute of Electrical and Electronics Engineers Inc., 2018-11) Kacmaz, Rukiye Nur; Yilmaz, Bulent
    Ulcerative colitis (UC) is a disease in which inner surface of colon is inflamed. Ulcers and open scars on the colon are observed. The complaint in the flare period is the frequent bloody diarrhea. Complaints of people with UC increase and decrease periodically. Colonoscopy is the most preferred approach for the visualization of the gastrointestinal tract for the diagnosis and follow-up of related diseases, and UC in particular. The lack of experience of the colonoscopist, complicated locality of the lesion, and the rush in the colonoscopy suite to complete the procedure as soon as possible may cause mistakes in visual analysis. In this study, 200 colonoscopy images (100 normal, 100 UC) were used. The statistical features such as gray level variance, gray level local variance, normalized variance, histogram range, and entropy were extracted from the images, and a normalized 200x5 feature matrix was formed. The normal images and images with UC were discriminated using support vector machines and k-nearest neighbors. It should be noted that the extraction of only 5 features from the colonoscopy images resulted in 95% accuracy. This study demonstrated the feasibility of the development of software tools for aiding the physicians in the diagnosis of colon diseases. © 2019 Elsevier B.V., All rights reserved.